Raw water quality: TDS < 200ppm, water pressure 0.10~ 0.40MPa, water temperature 5~45℃
Process: raw water /RO water /EDI water /RO pure water / ultra-pure water
Ultra Pure Water Amount: 10/20 (L/H)
Dimension: 380W*505D*620H (mm)
Net Weight: 35 (KGS)
Water Tank: 30L aseptic water tank (Double medical grade PE, standard breathing apparatus and water intake faucet, optional UV)
Application: AAS, AES, IC, HPLC, ICP/MS, VOC, IVF, PCR, liquid/gas chromatography, amino acid analysis, protein purification, electrophoresis /gel analysis, Toxicological analysis, animal and plant cell culture, Molecular Biology, Gene Research, in vitro baby.....
Product Series | CLEARP-EDI-Table Series | |||
Model | CLEARP-I-10/20ET | CLEARP-II-10/20ET | CLEARP-III-10/20ET | CLEARP-IV-10/20ET |
Raw water quality | TDS < 200ppm, water pressure 0.10~ 0.40MPa, water temperature 5~45℃ | |||
Produce water amount | 10/20 (L/H) | |||
Ultraviolet digestion apparatus | N/A | 60W 85/254nm | 60W 85/254nm | |
UF | N/A | 5000 Dalton | N/A | 5000 Dalton |
EDI Water Quality | Resistivity ≥ 10mω.cm@25 ℃ (online monitoring) | |||
RO Water Quality | Conductivity: 1 ~ 5μS/cm (on-line monitoring) | |||
Produced Water Quality | Resistivity: 18.2 mω.cm@25 ℃ (online monitoring) | |||
Fine Particulate Matter | ≤1 PC /ml | |||
TOC | ≤15ppb | ≤10ppb | ≤8ppb | ≤5ppb |
Microorganism | ≤1CFU/ML | |||
RNASES | <0.5pg/ml | |||
DNASES | <5pg/ml | |||
Heavy Metal Ion | ≤0.1ppb | |||
Terminal MF | 0.22μm inlet terminal MF | |||
Dimension | 380W*505D*620H (mm) | |||
Net Weight | 35 (KGS) | |||
Power | AC220V-50HZ ( 200-410W) or customized | |||
Water Tank | 30L aseptic water tank (Double medical grade PE, standard breathing apparatus and water intake faucet, optional UV) | |||
Application | AAS, AES, IC, HPLC, ICP/MS, VOC, IVF, PCR, liquid/gas chromatography, amino acid analysis, protein purification, electrophoresis /gel analysis, Toxicological analysis, animal and plant cell culture, Molecular Biology, Gene Research, in vitro baby..... |
Features:
1. User management: password protection.
2. Multiple water intake: fast water intake / appointment water intake / fixed quality and volume water intake.
3. Water intake display: online display of water intake type/temperature/water quality/flow/water intake volume.
4. Flow monitoring: online monitoring of raw water /RO water /EDI water /RO pure water / ultra-pure water flow, timely record the water volume (about 5% difference when big volume).
5. Six-way water quality monitoring: online monitoring of raw water /RO water /EDI water /RO water intake / UP water intake water quality and temperature /UP ultra-pure water TOC (optional).
6. Consumables/accessories management: online monitoring the life of pre-treatment /RO /pre-ultra-purification/ultra-purification/UV lamp /UF.
7. Cycle antibacterial: through water intake cycle, standby cycle and multiple cycle technology, to achieve efficient inhibition of bacterial regeneration.
8. Sterilization: Through dual-wavelength (185/254nm) ultraviolet, effective sterilization and reduce TOC value.
9. Data management: record and store previous failure records/water intake records/consumables replacement records, complete Excel table data can be downloaded through the USB port, real-time record printing (optional), to achieve data traceability.
10. System protection alarm: water shortage protection alarm/high and low liquid level protection alarm/special consumables identification alarm/water unqualified alarm/consumables accessories up to rated value alarm/fault alarm/water leakage protection (optional).
11. Excessive discharge: It can prevent unqualified RO water from entering the water system in the early stage of RO film operation (10-60 seconds).
12. Automatic flushing: unique pre-treatment filter element flushing and reverse osmosis membrane flushing, better water quality.
13. 2-stage pressure regulation: ensure inlet pressure and flow, reduce wastewater discharge and save water.
14. Applicable for wider water quality source.
15. Miniaturized continuous electric de-mineralization module (EDI), which produces 10~15ml of water to ensure the intake water quality of the ultra-purified column.
16. Extend the life time of the ultra-purified column and reduce the consumption of consumables.
Remarks:
1. E series has an intermediate water tank (capacity 100L), stand series has no intermediate water tank.
2. The open PE aseptic water tank is equipped with a multi-functional respirator to block the bacteria in the air from entering the pure water tank.
3. The product water volume refers to the RO water volume when the water temperature is 25℃, and the water production of RO decreases by about 3% as the water temperature drops by 1℃. When the water temperature is below 5℃, RO will stop producing water.
4. The quality of the incoming water will have a direct impact on the quality of the produced water and the life of the filter. After the water softener is added, it can be used in areas with poor source water quality (400μS/cm≤ conductivity ≤2000μS/cm).
5. It is recommended to choose the automatic softening system , which can effectively reduce the consumption of consumables for the subsequent system.