Product Categary: Industrial Membrane Element
Feature: High rejection rate and low working pressur
e-mail: info@scclearpure.com
Tel: +86-13699279286 (whatsapp)
It is applicable to the desalination of municipal water, groundwater with salt concentration less than 1500ppm. It can be widely used in residential dual water supplying system, pure water preparation plant, industry, food production and other fields etc.
Specifications & Parameters
Model | Active Mebrane Area ft2 (m2) | Concentrate Channel Space (mil) | Permeate Flow GPD(m3/d) | Stable Rejection Rate (%) | Minimum Rejection Rate (%) |
BW-8040-FR | 365(33.9) | 34 | 9500(35.9) | 99.7% | 99.6% |
Standard Test Condition
Concentration of Solution (NACL) | Temperature (℃) | pH Value | Operation Pressure PSI (MPa) | Recovery Rate (%) |
2000mg/L | 25 | 7.5-8 | 225(1.55) | 15% |
Notes: The permeate flow of single membrane element may vary with in ±15%.
Operating Limits and Conditions of Membrane Element:
Max.Working Pressure | 600 psi(4.14MPa) |
Max. FeedWater Temperature | 45 ℃ |
Max. FeedWaterSDI15 | 5.0 |
Max. Feed Water Flow | 17m3/h |
Free Chlorine Concentration of FeedWater | 0.1mg/L |
pH Range of Feed Water During Continuous Operation | 3-10 |
pH Range of FeedWaterDuring Chemical Cleaning | 1-13 |
Max. Pressure Drop of Single Membrane Element | 15psi(0.1Mpa) |
It is applicable to the desalination of municipal water, groundwater with salt concentration less than 1500ppm. It can be widely used in residential dual water supplying system, pure water preparation plant, industry, food production and other fields etc.