Residential Series RO Membrane Element-RO-2012-100

Product Categary:Residential Membrane Element 

Main Feature:High rejection rate and low working pressure. 

Tel: +86-13699279286  (Whatsapp) 

Email: info@scclearpure.com


It is widely applicable to household water purification, direct drinking in building or office and other small water purification equipment etc

 
 Specifications & Parameters

   Model

Active Mebrane Area ft2 (m2)

Permeate Flow GPD(m3/d)

Stable Rejection Rate (%)

Minimum Rejection Rate (%)

RO-2012-100

6.3(0.59)

100(0.38)

95%

98%


Standard Test Condition


     Test Methods

Concentration of Solution (NACL)

Temperature (℃)

pH Value

Operation Pressure PSI (MPa)

Recovery Rate (%)

   A

500mg/L
     (NaHCO3、CaCl2、NaCl)

25

7.5-8

60(0.41)

50

    B

250mg/L NaCl

25

7.5-8

60(0.41)

20-30

Notes: The permeate flow of single membrane element may vary with in ±15%.


Operating Limits and Conditions of Membrane Element:

Max.Working Pressure

300 psi(2.07MPa)

Max. FeedWater Temperature

45 ℃

Max. FeedWaterSDI15

5.0

Free Chlorine Concentration of FeedWater

0.1mg/L

pH Range of Feed Water During Continuous Operation

3-10

pH Range of FeedWaterDuring Chemical Cleaning

2-12

Max. Pressure Drop of Single Membrane Element

10psi(0.07Mpa)